Vibration standards

The Frogwatch Dashboard lets you define vibration standards flexibly. This makes it very easy to measure against different standards. A distinction is currently made between damage standards and nuisance standards. Damage standards can be defined in both the acceleration domain and the velocity domain, so both SBR A and SBR C are supported. Nuisance standards measure according to the SBR B guideline.

Damage standards (SBR A and SBR C)

Go to the Standards main menu item and click Damage standards. This shows a list of all standards that have been created.

Defining a standard

Click + NEW STANDARD at the top of the list. The standard is defined by frequency - acceleration/velocity pairs. Choose the type of standard: velocity or acceleration. Then add a number of data points that together form a standard through interpolation. Choose a unique name for the standard and click SAVE. The standard now appears in the list.

SBR A standard.

Nuisance standards (SBR B)

As described in the SBR B guideline, a nuisance standard consists of the limits A1, A2 and A3 per period: day (07:00 to 19:00), evening (19:00 to 23:00) and night (23:00 to 07:00).

Defining a standard

Go to the Standards main menu item and click Nuisance standards. This shows a list of all standards that have been created. Click + NEW STANDARD at the top of the list. A popup appears with 10 input fields: A1, A2 and A3 for the day, the evening and the night, and 1 field for the unique name of the standard.